  14.  I................................................................ Overview
  15.  II............................................................... DATU
  16.  III.............................................................. SOLTS
  17.  IV............................................................... FAST
  18.  V................................................................ Conclusion
  19.  
  20.  
  21. =-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=
  22.  
  23.  
  24.  
  25.  
  26.                              +----------+
  27.                              +  Part I  +
  28.                              +          +
  29.                              +   --     +
  30.                              +          +
  31.                              + Overview +
  32.                              +----------+
  33.  
  34.  
  35. A VRS (Voice Response System) is a computer system that is called using
  36. a normal DTMF (Dual-Tone Multi-Frequency) telephone and interacted with
  37. by speaking or by pressing buttons on the telephone keypad.
  38.  
  39. This article will discuss three such systems which are used by LLC Local
  40. Loop Carriers (LLCs) to maintain the Public Switched Telephone Network
  41. (PSTN). The systems are:
  42.  
  43.                 . DATU
  44.                 . SOLTS
  45.                 . FAST
  46.  
  47.  
  48.                 +-------------------------------------+
  49.                 +              Part II                +
  50.                 +                                     +
  51.                 +                --                   +
  52.                 +                                     +
  53.                 + DATU LC/RT Loop Conditioning System +
  54.                 +-------------------------------------+
  55.  
  56.  
  57. I.    Introduction
  58. II.   Features
  59. III.  Usage
  60. IV.   Part Numbers
  61.  
  62.  
  63. Introduction
  64. ~~~~~~~~~~~~
  65.  
  66. The Harris Corporation's DATU Loop Conditioning System combines a full
  67. range of advanced features with unmatched versatility to help maximize
  68. field testing and conditioning capabilities. The DATU system extends the
  69. field technicians testing capabilities of subscriber lines through the
  70. non-metallic environment of a pair gain system.
  71.  
  72. DATU is a printed wiring card that employs micro-processor control of
  73. test functions and provides voice prompting. The card is installed in
  74. the Metallic Facility Terminal (MFT) frame and connected through a
  75. No-Test trunk to a switching facility. It may be used with most types of
  76. Central Offices (CO) including SXS, Crossbar, ESS and DMS.
  77.  
  78. The DATU system can include the Pair Gain Applique (PGA) II, located
  79. with the DATU system at the CO, and the Metallic Access Unit (MAU),
  80. which is mounted within a remote terminal.
  81.  
  82. PGA units allow testing of subscriber lines being served through an
  83. SLC-96 pair gain system. The PGA provides an interface between the DATU
  84. and a Pair Gain Control Unit. The DATU will transmit tones to assist in
  85. determining the status of the carrier channel. When a subscriber line is
  86. being served by a pair-gain-system and the DATU is used to test it, a
  87. warble tone is heard. The warble tone is followed by either a single
  88. one-second tone, two one-second tones, or three one-second tones. This
  89. indicates either a single party channel, multi party channel or a coin
  90. channel. The absence of a tone indicates trouble with the channel or
  91. channel equipment.
  92.  
  93.  
  94. Features
  95. ~~~~~~~~
  96.  
  97. AUDIO MONITOR - The subscriber line may be monitored for up to 10
  98. minutes, after which time the DATU disconnects from the No-Test trunk.
  99. Audio Monitor may be used on either busy or idle lines. Traffic on a
  100. busy line will be audible but unintelligible. The Audio Monitor Mode may
  101. be exited before the end of the 10 minute period by selecting an
  102. appropriate test function.
  103.  
  104. OPEN LINE - Opens subscriber line by removing battery and ground.
  105.  
  106. SHORT LINE - A metallic short is placed across the tip and ring of the
  107. subscriber line.
  108.  
  109. SHORT TO GROUND - A metallic connection between tip, ring, and ground.
  110. This feature is not available on a busy line.
  111.  
  112. TIP TO GROUND - A metallic connection between tip and ground with the
  113. ring open.
  114.  
  115. RING TO GROUND - A metallic connection between ring and ground with the
  116. tip open.
  117.  
  118. HIGH LEVEL TEST TONE - A high level 577Hz metallic-tracing tone,
  119. interrupted four times per second, for identity purposes. The High Level
  120. Test Tone is not available on a busy line.
  121.  
  122. HIGH LEVEL TONE ON TIP - Test tone is placed only on the tip side of the
  123. line, with the ring side grounded.
  124.  
  125. HIGH LEVEL TONE ON RING - Test tone is placed only on the ring side of
  126. the line, with the tip side grounded.
  127.  
  128. LOW LEVEL TEST TONE - A low level 577Hz simplex-tracing tone,
  129. interrupted four times per second, for identity purposes. The Low Level
  130. Test Tone may be applied even if the line under test is busy, and it
  131. will not disturb traffic on that line. Note that on some No.5 ESS
  132. switches, Simplex tone may not transmit.
  133.  
  134. SINGLE LINE ACCESS - Allows conditioning functions on the same line used
  135. to access the DATU system.
  136.  
  137. HOLD - Used to continue a line preparation function after disconnecting
  138. from the system's access line.
  139.  
  140. FORCED DISCONNECT - Allows the technician to disconnect from the system
  141. at any time by dialing ##.
  142.  
  143. ADMINISTRATIVE - Password protection for both user and administrator
  144. modes of access. System usage counters and timers are accessible through
  145. interactive voice response.
  146.  
  147.  
  148. DATU Usage
  149. ~~~~~~~~~~
  150.                 Dial DATU Number.
  151.                 Dial User Security Code.
  152.                 Dial 7 Digit Subscriber Number.
  153.  
  154.                           / \
  155.                         /     \
  156.                       /         \
  157.                     /             \
  158.                   /                 \
  159.                 /                     \
  160.                |                       |
  161.  
  162. Normal Subscriber Line          SLC Subscriber Line
  163. ~~~~~~~~~~~~~~~~~~~~~~          ~~~~~~~~~~~~~~~~~~~
  164. OK                              8 second warble
  165.                |                       -then-
  166.                |                60 IPM busy:   Pair Gain Test Controller Alarm
  167.                |                        -or-
  168.                |                120 IPM Busy:  Busy test pair
  169.                |                        -or-
  170.                |                1 second tone: One party line
  171.                |                        -or-
  172.                |                2 second tone: Two party line
  173.                |                        -or-
  174.                |                3 second tone: Pay phone
  175.                |                        -or-
  176.                |                No tone:        Bad carrier channel
  177.                |
  178.                |                       |
  179.                 \                     /
  180.                   \                 /
  181.                     \             /
  182.                       \         /
  183.                         \     /
  184.                           \ /
  185.  
  186.                 Enter DATU function code for condition:
  187.  
  188.                 1  Menu
  189.                 2  Audio Monitor
  190.                 3  Short Tip and Ring to Ground
  191.                 4  High Level Coiling Tone
  192.                 5  Low Level Simplex Tone
  193.                 7  Short Tip to Ring
  194.                 *  Continue test after disconnect (1 = 1 minute, 0=10 minutes)
  195.                 #  Enter new seven digit subscriber number
  196.  
  197.  
  198. Harris DATU Part Numbers
  199. ~~~~~~~~~~~~~~~~~~~~~~~~
  200.  
  201. DATU-LC Loop Conditioning System        P/N 24820-001
  202. PGA IIS                                 P/N 24810-002
  203. DATU-RT Loop Conditioning System        P/N 24820-003
  204. TSA                                     P/N 24800-103
  205. DATU-RT (GTD-5 Version)                 P/N 24820-005
  206. TDC                                     P/N 24800-102
  207. Metallic Access Unit                    P/N 24840-002
  208. MFT Card File                           P/N 25460-002
  209. Metallic Access Unit (RSU version)      P/N 24845-005
  210.  
  211.  
  212.  
  213.  
  214.  
  215.                   +----------------------------------+
  216.                   +            PART III              +
  217.                   +                                  +
  218.                   +             --                   +
  219.                   +                                  +
  220.                   + Small Office Loop Testing System +
  221.                   +                                  +
  222.                   +            (SOLTS)               +
  223.                   +----------------------------------+
  224.  
  225.  
  226. Small Office Loop Testing System (SOLTS) is a system used by telephone
  227. company field repair personnel to test a phone line from any touch-tone
  228. telephone.
  229.  
  230. When dialing a SOLTS number, the first prompt is:
  231.  
  232.         ~Please enter ID, terminate with #~
  233.  
  234. SOLTS allows 30 seconds to enter a correct ID, then prompts:
  235.  
  236.         ~Please enter line number and press #~
  237.  
  238. SOLTS allows 60 seconds to enter a line number, then prompts:
  239.  
  240.         ~Select mode, for help enter 0~
  241.  
  242. SOLTS allows 60 seconds to choose one of six options:
  243.  
  244.  
  245. Enter:
  246.  
  247. 1) Interactive Testing
  248. 2) Calling on test line
  249. 3) Retrieve results
  250. 8) Hang up
  251. 9) Enter line number
  252. 0) Help
  253.  
  254.  
  255. Option one allows testing the telephone line connected to the number
  256. entered in step two above. Option two tests the line the technician is
  257. calling from. Option three is used to retrieve the results generated
  258. using options one and two. Option eight disconnects from the system.
  259. Option nine allows a new line number to be entered for testing. Option
  260. zero accesses on-line help.
  261.  
  262.  
  263.     Mode 1 -- Interactive Testing
  264.     ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  265.  
  266.     #) Line test
  267.     1) Fault Location
  268.     2) Special tests
  269.     3) Completion Test
  270.     8) Hang up
  271.     9) Enter line number
  272.     0) Help
  273.  
  274.  
  275.         Line Test
  276.         ~~~~~~~~~
  277.         Perform a line test on the number entered, then:
  278.  
  279.         7) Repeat Results
  280.         8) Hang up
  281.         9) Enter line number
  282.         0) Help
  283.  
  284.  
  285.         Fault Location
  286.         ~~~~~~~~~~~~~~
  287.         Performs initial line test on the number entered, then:
  288.  
  289.         2) Next step
  290.         7) Repeat results
  291.         8) Hang up
  292.         9) Enter line number
  293.         0) Help
  294.  
  295.  
  296.         Special Tests
  297.         ~~~~~~~~~~~~~
  298.         Performs initial line test on the number entered, then:
  299.  
  300.         #) Repeat line test
  301.         2) Loop and Ground
  302.         3) Pull dial tone
  303.         5) Pair ID Tone
  304.         7) Repeat results
  305.         8) Hang up
  306.         9) Enter line number
  307.         0) Help
  308.  
  309.  
  310.         Completion Test
  311.         ~~~~~~~~~~~~~~~
  312.  
  313.         Performs a line test on the number entered, records the results,
  314.         then requests:
  315.  
  316.         7) Repeat results
  317.         8) Hang up
  318.         9) Enter line number
  319.         0) Help
  320.  
  321.  
  322.     Mode 2 -- Calling On Test Line
  323.     ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
  324.  
  325.         #) Line Test
  326.         3) Completion Test
  327.         8) Hang up
  328.         9) Enter line number
  329.         0) Help
  330.  
  331.  
  332.         Line Test
  333.         ~~~~~~~~~
  334.  
  335.         Performs a line test on the number entered, if line is busy
  336.         requests Craft to hang up, performs a line test and stores the
  337.         results.
  338.  
  339.         8) Hang up
  340.         9) Enter line number
  341.         0) Help
  342.  
  343.         Completion Test
  344.         ~~~~~~~~~~~~~~~
  345.  
  346.         Performs a line test on the number entered, if line is busy
  347.         requests Craft to hang up, performs a line test, and records the
  348.         results.
  349.  
  350.         8) Hang up
  351.         9) Enter line number
  352.         0) Help
  353.  
  354.  
  355.     Mode 3 -- Retrieve Results
  356.     ~~~~~~~~~~~~~~~~~~~~~~~~~~
  357.  
  358.         States the stored results for the line number entered, then:
  359.  
  360.         7) Repeat results
  361.         8) Hang up
  362.         9) Enter line number
  363.         0) Help
  364.  
  365.  
  366.  
  367.  
  368.  
  369.                       +---------------------------+
  370.                       +         PART IV           +
  371.                       +                           +
  372.                       +            --             +
  373.                       +                           +
  374.                       + Field Access Service Tool +
  375.                       +                           +
  376.                       +        (F.A.S.T.)         +
  377.                       +---------------------------+
  378.  
  379. When calling FAST, the first prompt is a request for a security code.
  380. The security code is usually the employee badge number. After the
  381. security code is entered and the # key is pressed, FAST will prompt for
  382. the password. The password is usually 4-7 digits long and usually
  383. expires every 30 days. The default password is usually the security
  384. code. After the password is entered and the # key is pressed the FAST
  385. New Notices and Features are played.
  386.  
  387. After all of that, the FAST Main Menu is made available:
  388.  
  389. FAST Main Menu
  390.  
  391. 1. Facilities Inquiry
  392. 2. MLT Test
  393. 3. Cut to new facilities
  394. 4. Change Status of a cable and pair
  395. 5. Test Caller-ID
  396. 6. Close a Service Order
  397. 7. Cable transfer (for splicers)
  398. 8. Administrative
  399. 9. News and documentation
  400. 0. Connect call to Help Line
  401.  
  402. 1:    LFACS Inquiry
  403.     1. by phone number
  404.     2. by cable pair
  405.  
  406.     1:    Enter telephone number
  407.         1. Correct
  408.         2. Re-enter
  409.  
  410.         1. Current assignment
  411.         2. Spare pairs
  412.         3. Multiple appearances
  413.  
  414.         1. F1 (feeder)
  415.         2. F2 (distribution)
  416.         3. F3 (if any)
  417.         4. All facilities in loop
  418.  
  419.     2:    Enter wire center NXX
  420.         1. Correct
  421.         2. Re-enter
  422.  
  423.         Enter cable number
  424.         1. Correct
  425.         2. Re-enter
  426.  
  427.         Enter pair count
  428.         1. Correct
  429.         2. Re-enter
  430.  
  431.         1. Current status
  432.         2. Spare pairs
  433.         3. Multiple appearances
  434.         4. Defective pair list
  435.         5. Another cable-pair
  436.         6. Another pair, same cable
  437.  
  438.  
  439. 2:    MLT test
  440.     1. Quick
  441.     2. Loop
  442.     3. Full
  443.     4. Add tone
  444.     5. Remove tone
  445.  
  446.     Tone: Enter telephone number
  447.     1. Correct
  448.     2. Re-enter
  449.     
  450.     Add tone - enter number of minutes of tone #
  451.  
  452.     1. Another request
  453.     2. End call
  454.     3. Wait for tone
  455.  
  456.  
  457. 3:    Cut to new facilities
  458.     1. Service Order
  459.     2. Trouble Ticket
  460.  
  461.     1:    Service Order
  462.         1. C-Order
  463.         2. N-Order
  464.         3. T-Order
  465.         4. Other
  466.  
  467.         Enter 6 digit numeric portion of order number
  468.         1. Correct
  469.         2. Re-enter
  470.     
  471.         +-----------------------------------+
  472.         | Go to "Hear F1 assignment" below. |
  473.         +-----------------------------------+
  474.     
  475.     2:    Trouble Ticket
  476.         Enter telephone number
  477.         1. Correct
  478.         2. Re-enter
  479.  
  480.         Hear F1 assignment
  481.         1. Cut
  482.         2. Keep
  483.  
  484.         Hear F2 assignment
  485.         1. Cut
  486.         2. Keep
  487.  
  488.         Hear F3 assignment
  489.         1. Cut
  490.         2. Keep
  491.  
  492.         +------------------------------------------+
  493.         | Go to "Specify code for bad pair" below. |
  494.         +------------------------------------------+
  495.  
  496.  
  497. 4:    Change status of a cable/pair to defective or non-defective
  498.  
  499.         Specify code for bad pair
  500.         1. GTP
  501.         2. OPN
  502.         3. OTP
  503.         4. UBL
  504.         5. SHT
  505.         6. GRG
  506.         7. CBY
  507.         8. Other
  508.  
  509.             Other
  510.             1. Non-defective
  511.             2. Defective, unknown
  512.             3. Exposed
  513.             4. Split pair
  514.             5. Previous list
  515.  
  516.         Specify pair to use
  517.         
  518.         Enter new cable number or only # if no change
  519.         1. Correct
  520.         2. Re-enter
  521.  
  522.         Enter new pair number
  523.         1. Correct
  524.         2. Re-enter
  525.  
  526.                 FAST pages the technician to indicate the success
  527.                 of the cut.
  528.  
  529.         Note: If F1 is being cut both LFACS and COSMOS need
  530.                       updates. Two pager messages will be sent.
  531.  
  532.                       If CF pair is used as spare, information will be
  533.                       given to break connection.
  534.  
  535.  
  536. 5:     Test Caller-ID
  537.     Enter 7 digit telephone number to be called.
  538.     1. Correct
  539.     2. Re-enter
  540.     3. Correct and calling from the number
  541.  
  542.  
  543. 6:      Close Service Order
  544.     1. C-Order
  545.     2. N-Order
  546.     3. T-Order
  547.     4. Other
  548.  
  549.     Enter 6 digit numeric portion of order number
  550.     1. Correct
  551.     2. Re-enter
  552.  
  553.     1. Closed today
  554.     2. Closed yesterday
  555.     3. Other
  556.  
  557.  
  558. 7:    Cable transfer
  559.     Enter TN from cut sheet
  560.     1. Correct EWO.xfer
  561.     2. Re-enter TN
  562.  
  563.     Enter first item number
  564.     Enter last item number
  565.     1. Correct
  566.     2. Re-enter
  567.  
  568.     To transfer this item:
  569.     1. Move to new equipment
  570.     2. Skip this item
  571.  
  572.  
  573. 8:    Administrative
  574.     1. Change Password
  575.     2. Change 3 digit EC
  576.     3. Change 3 digit NPA
  577.  
  578.  
  579. 9:    FAST News
  580.  
  581.  
  582. 0:    FAST Help Line
  583.  
  584.  
  585. Notes:  When entering a variable number of digits, # is required to end entry.
  586.         When entering a fixed number of digits, # is not required.
  587.         Pressing 9 will always return to the main menu.
  588.  
  589.     To enter alpha characters press * to enter alpha mode and then
  590.         use the following key sequences. Use * again to exit alpha mode.
  591.  
  592.     For example: Voy866 would be *836393*866.
  593.  
  594.     A    21
  595.     B    21
  596.     C    23
  597.     D    31
  598.     E    32
  599.     F    33
  600.     G    41
  601.     H    42
  602.     I    43
  603.     J    51
  604.     K    52
  605.     L    53
  606.     M    61
  607.     N    62
  608.     O    63
  609.     P    71
  610.     Q    01
  611.     R    73
  612.     S    73
  613.     T    81
  614.     U    82
  615.     V    83
  616.     W    91
  617.     X    92
  618.     Y    93
  619.     Z    03
  620.     -    11
  621.     .    12
  622.     +    13
  623.  
  624.  
  625.  
  626.  
  627.  
  628.                              +------------+
  629.                              +   Part V   +
  630.                              +            +
  631.                              +    --      +
  632.                              +            +
  633.                              + Conclusion +
  634.                              +------------+
  635.  
  636.  
  637. Voice Response Systems can be a great deal of fun, and they can be
  638. safely accessed from a public telephone. Don't play with these from
  639. home. VRSs are a great way to hack without using a computer.
  640.  
  641. For information on the Teradyne 4Tel VRS System, read the LOD/H
  642. Technical Journal, Issue #3: File 05 of 11: An Overview of the Teradyne
  643. 4Tel System by Doom Prophet LOD/H.
  644.  
  645.  
  646. ----[  EOF
  647.  
  648.